[Other] [Agreement analysis and result calibration by ordinary least product regression between bioelectrical impedance analysis and dual energy X-ray absorptiometry]

aamato1979 Post time 12 min. ago | Show all posts |Read mode
This post will be closed automatically in 2026-11-30 00:48
Reward50points

https://oversea.cnki.net/kcms2/article/abstract?v=x4STSzS3xmwa7SrbwWhvu9Vk7VJ-TSnNvaRJ01iCFaNlvluhfI2TMT2Avtsz2QWbXuR599cxwdGVCowz-ZSPes7VM3JmNfmwMGbDrNp5JxnQXWTPKAtEJsiU2vE35mApOyRx5_USt61V4EoGyct_AJBRG1dOAWjq9P3_MAil10uVriA4u7SE-sBkMnOmCRao&uniplatform=OVERSEA&language=CHS&captchaId=3cef6c64-310f-4074-802b-942830c1d438#


Wei Sheng Yan Jiu




. 2021 May;50(3):426-431.

doi: 10.19813/j.cnki.weishengyanjiu.2021.03.013.
[Agreement analysis and result calibration by ordinary least product regression between bioelectrical impedance analysis and dual energy X-ray absorptiometry][Article in Chinese]
Xiaoyun Song 1, Huijun Wang 1, Chang Su 1, Yifei Ouyang 1, Zhimei Lyu 1, Nan Wei 1, Yan Li 1, Yuxia Ma 2, Qingxia Li 2, Bing Zhang 1


Affiliations Expand

Abstract
Objective: To analyze agreement of body fat percentage measured by bioelectrical impedance analysis(BIA) and dual energy X-ray absorptiometry(DXA) in Chinese adults, and to calibrate BIA measurement by ordinary least product regression(OLP).
Methods: Volunteers aged 18-65 were recruited to measure total body fat percentage and trunk fat percentage by BIA(Tanita BC-601 F) and DXA(Hologic Discovery QDR), respectively. Agreement between the two methods was compared by OLP. Bootstrap method was used to do the internal validation of the calibration equation. The calibration effect was verified by the agreement analysis of the calibrated BIA result and the DXA result.
Results: Before calibration, all 95%CIs of the intercepts of the OLP regression lines did not include 0, and all 95%CIs of the slopes of the OLP regression lines did not include 1. 00. After calibration, all 95% CIs of the intercepts of the OLP regression lines included 0, and all 95% CIs of the slopes included 1. 00.
Conclusion: There are fixed bias and proportion bias between BIA and DXA in measuring total body fat percentage and trunk fat percentage in Chinese men and women. Calibration should be considered when body fat percentage is measured by BIA.

Keywords: bioelectrical impedance analysis; body fat percentage; calibration; dual energy X-ray absorptiometry; ordinary least product regression.