[Other] A dual-band radio-frequency biosensing platform with physics-informed deep learning for simultaneous sweat pH and lactate monitoring

mkkmkk Post time 1 hour(s) ago | Show all posts |Read mode
This post will be closed automatically in 2026-11-05 00:35
Reward10points

TY  - JOUR
AU  - Miao, Fengjuan J.
AU  - Wang, Huixin
AU  - Tao, Bairui R.
PY  - 2026
DA  - 2026/08/01
TI  - A dual-band radio-frequency biosensing platform with physics-informed deep learning for simultaneous sweat pH and lactate monitoring
JO  - Microchimica Acta
SP  - 591
VL  - 193
IS  - 8
AB  - Continuous monitoring of sweat pH and lactate is of great value for physiological assessment, yet existing sensors face two critical bottlenecks: prolonged response times that hinder real-time tracking, and signal decoding relying on simple linear calibration that fails to handle nonlinearities and dynamic hysteresis. Here, we report a synergistic ※RF每materials每AI§ dual-band biosensing platform integrating (1) a stub-loaded dual-resonance microstrip antenna at 2.61 GHz and 3.98 GHz for frequency-domain discrimination of pH and lactate responses; (2) ternary nanocomposite interfaces〞rGO/TiO₂/MWCNTs for pH and rGO/CuO/NiCo-MOF for lactate〞for dielectric modulation and redox-mediated charge transfer, respectively; and (3) a Physics-BiLSTM-Attention network embedding first-order temporal difference priors and a dual-branch attention mechanism for robust multiparameter regression. The sensor achieves response times of 55 s (pH) and 135 s (lactate) with good stability and selectivity. On human sweat data from 10 subjects under LOSO-CV evaluation, the model delivers lactate prediction with R = 0.98, R²=0.96, MAE = 0.87 mM, RMSE = 1.12 mM, and pH prediction with R = 0.94, R²=0.88, MAE = 0.12 pH units, RMSE = 0.15 pH units〞substantially outperforming static calibration (29.8% and 31.4% MAE reduction, respectively). The model achieves 94.0% accuracy in health status classification and 91.2% in exercise intensity classification, with well-calibrated uncertainty $$\:\text{PICP}\text{=87.3}$$. Ablation studies confirm that removing any core component degrades MAE by 27每73%, underscoring the indispensable synergy of the three design dimensions. This work establishes a materials每hardware每algorithm co-design framework for multiparameter sweat analysis, offering a conceptually new pathway toward intelligent, passive, and continuous biosensing.
SN  - 1436-5073
UR  - https://doi.org/10.1007/s00604-026-08309-8
DO  - 10.1007/s00604-026-08309-8
ID  - Miao2026
ER  -


Reply

Use magic Donate Report

All Reply0 Show all posts

Reply

You have to log in before you can reply Login | Register

Points Rules

Intermediate member
  • post

  • reply

  • points

    490


Return to the list